DKI Jakarta - Jakarta Pusat

HI 351202

Harga :
Rp. 1 / unit
Merk :
HANNA
Pembelian Minimal :
1 unit
Pengiriman :
3 hari sejak pembayaran
Lokasi :
DKI Jakarta - Jakarta Pusat
Dilihat :
4 Kali
Update Terakhir :
19-06-2019 13:16

Detail Produk

Spesifikasi HI 351202

PH Meter

Description

Hanna Hanna HI 3512-02 Calibration adalah 2 channel bangku profesional top meter dengan grafis LCD, dirancang untuk memberikan hasil laboratorium yang akurat.

Channel 1 memiliki kemampuan pH / ORP / ISE dan suhu pengukuran, sedangkan saluran 2 langkah EC / TDS / NaCl / Tahanan dan suhu.

Hanna Hanna HI 3512-02 Calibration log-on demand hingga 400 sampel dan juga menyediakan dipilih pengguna ‘dari kalibrasi range’ peringatan.

features Hanna Hanna HI 3512-02 Calibration

  • Up to five point pH calibration with seven standard buffers
  • Up to five point ISE calibration with six standard solutions
  • 0.001 pH resolution
  • GLP features
  • Automatic Temperature Compensation
  • PC interface via USB
  • Log on demand of up to 400 samples

Supplied with

  • HI-76310 conductivity/TDS probe
  • HI-1131B pH electrode
  • HI 7662-T temperature probe
  • Starter pack of buffer and cleaning solutions
  • HI-76404N electrode holder
  • 12Vdc adapter
  • Instructions

Hanna Instruments HI 3512 Dua Channel, pH / ORP / ISE, EC / TD / NaCl / Tahanan Benchtop Meter adalah 2 channel profesional benchtop meter dengan grafis LCD, dirancang untuk memberikan hasil laboratorium yang akurat. Channel 1 memiliki pH / ORP / ISE dan suhu kemampuan pengukuran sementara saluran 2 langkah EC / TDS / NaCl / Tahanan dan suhu. Saluran pH menawarkan hingga lima titik kalibrasi pH dengan tujuh buffer standar (pH 1,68, 4,01, 6,86, 7,01, 9,18, 10,01 dan 12,45) dan sampai dua buffer kustom.

Specifications Hanna Hanna HI 3512-02 Calibration

Range pH -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 16.000 pH
Range mV ±2000 mV
Range Selective Ions 1.00 E-7 to 9.99 E10 conc.
Range Temperature -20.0 to 120.0°C
Range EC 0.001 to 9.999 uS/cm; 10.00 to 99.99 uS/com; 100.0 to 999.9 uS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 999.9 mS/cm; 1000 mS/cm
Range Resistivity 01.0 to 199.9 ohms; 100 to 1.999 ohms; 1.00 to 19.99 Kohms; 10.0 to 199.9 Kohms; 100 to 1.999 Kohms; 1.00 to 19.99 Mohms; 10.0 to 100.0 Mohms
Range TDS 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L; 100.0 to 400.0 g/L
Range Salinity % NaCl: 0.0 to 400.0%
Resolution pH 0.1 pH; 0.01 pH; 0.001 pH
Resolution mV 0.1 mV
Resolution Selective Ions 3 digits 0.01, 0.1, 1, 10 conc.
Resolution Temperature 0.1°C
Resolution EC 0.001 uS/cm; 0.01uS/cm; 0.1 uS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
Resolution Resistivity 0.1 ohm; 1 ohm; 0.01 Kohms; 0.1 Kohms; 1 Kohms; 0.01 Mohms; 0.1 Mohms
Resolution TDS 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/L
Resolution Salinity 0.1%
Accuracy pH ±0.01 pH / ±0.002 pH
Accuracy mV ±0.2 mV
Accuracy Selective Ions ±0.5% of reading
Accuracy Temperature ±0.2°C
Accuracy EC ±1% of reading
Accuracy Resistivity ±1% of reading
Accuracy TDS ±1% of reading
Accuracy Salinity ±1% of reading
BNC Inputs   1 for pH electrode + 1 for ISE electrode
Calibration Check   yes
Relative mV Offset Range   ±2000 mV
pH Calibration   automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
ISE Calibration   Automatic, up to 5 point with 6 memorized values (0.1, 1, 10, 100, 1000, 10000 ppm)
Temperature Compensation   Automatic or manual, -20.0 to 120°C (-4 to 248°F)
pH Electrode   HI 1131B, glass body, refillable, BNC + pin connectors, 1 m cable (included)
Temperature Probe   HI 7662-T with 1 m (3.3′) cable (included)
Input Impedance   1012
Log-On-Demand   400 samples
Power Supply   12 Vdc adapter (included)
Environment   0 to 50°C (32 to 122°F); RH max 95%
Dimensions   235 x 207 x 110 mm
Weight   1.8 kg (4.0 lb.)

 

Harga HI 351202

 : CALL
 

Permintaan Penawaran