Spesifikasi K34710 BV3000 Brookfield Viscosity
Alat Laboratorium Umum
Test Method
Determines the low temperature, low shear rate viscosities of gear oils, automatic transmission fluids, hydraulic oils and other fluid lubricants by use of the Brookfield viscometer.
Features and Benefits
• Sample soaking and testing in a single bath, eliminating the need for an air bath and the risk of sample temperature rise during transfer
• Redesigned for improved control of sample movement and handling during testing
• Microprocessor PID temperature control duplicates the sample cooling rates in ASTM D2983
• Up to 40 cooling/testing temperature profiles can be stored in memory
• Redesigned turntable mechanism seals out moisture to minimize ice formation |
Click on the image to view a larger photo of the instrument. |
|
BV3000 Brookfield Viscosity Liquid Bath
Constant temperature liquid bath permits testing of samples without the risk of sample temperature rise. After cooling in the air bath, the sample must be transferred to the balsa cell carrier for testing with the Brookfield viscometer. If the sample is not tested quickly, there is the risk of sample temperature rise. The Brookfield Viscosity Liquid Bath eliminates this risk by permitting the sample to be tested in a constant temperature environment. The Brookfield viscometer mounts directly on the bath and the samples are rotated into position under the spindle by means of a built-in turntable. Cooling system maintains temperature with ±0.05°C stability in the range of +10°C to –55°C. Bath temperature is displayed in digital format.
Specifications
Conforms to the specifications of: Note 7 of ASTM D2983
Sample Capacity: 10 samples
Temperature Range: +10°C to –55°C
Temperature Control Stability: ±0.05°C
Electrical Requirements
115V 60Hz, Single Phase, 16A
220-240V 50 or 60Hz, Single Phase, 12A
Dimensions lxwxh,in.(cm)
17x24x25(43x61x25)
Net Weight: 265 lbs (120kg)
Shipping Information
Shipping Weight: 300 lbs (136kg)
Dimensions: 13.9 Cu. ft. |
|
Ordering Information |
|
Catalog
Number
|
Product Description
|
Electrical Requirements
|
K34710
|
BV3000 Brookfield Viscosity Liquid Bath
|
115V, 60Hz, 16A
|
K34711 |
BV3000 Brookfield Viscosity Liquid Bath |
220-240V, 50Hz, 12A |
K34712
|
BV3000 Brookfield Viscosity Liquid Bath
|
220-240V, 60Hz, 12A |
|
|
Accessories |
|
Catalog
Number |
Product Description |
Additional Information |
K34750 |
Brookfield Digital Viscometer |
115V, 60Hz |
K34751 |
Brookfield Digital Viscometer |
220-240V, 50Hz |
K34752 |
Brookfield Digital Viscometer |
220-240V, 60Hz |
K34760 |
Brookfield Programmable Viscometer |
115V, 60Hz |
K34761 |
Brookfield Programmable Viscometer |
220-240V, 50Hz |
K34762 |
Brookfield Programmable Viscometer |
220-240V, 60Hz |
K34706 |
Insulated Spindle No.4 |
|
K34704 |
Non-Insulated Spindle No.4 |
|
K34707 |
Cell Stopper |
|
K34708 |
Insulated Cell Carrier |
|
K34709 |
Test Cell - Round Bottom |
pack of 12 |
K34770 |
Test Cell - Flat Bottom |
pack of 12 |
250-000-122C |
ASTM 122C/IP94C Thermometer |
Range –45 to –35°C |
250-000-123C |
ASTM 123C/IP95C Thermometer |
Range –35 to –25°C |
250-000-124C |
ASTM 124C/IP96C Thermometer |
Range –25 to –15°C |
250-000-125C |
ASTM 125C/IP97C Thermometer |
Range –15 to –5°C |
355-005-027 |
Viscosity Standard N27B |
Viscosities in centipoise at –40, –30, –20, –15, –10, 0°F |
355-005-115 |
Viscosity Standard N115B |
Viscosity in centipoise at –20, –15, –10, 0, +10, +20°F |
|
|
Harga K34710 BV3000 Brookfield Viscosity
: CALL