DKI Jakarta - Jakarta Pusat

Automatic Aniline Point Apparatus

Harga :
Rp. 1 / unit
Merk :
KOEHLER
Pembelian Minimal :
1 unit
Pengiriman :
3 hari sejak pembayaran
Lokasi :
DKI Jakarta - Jakarta Pusat
Dilihat :
1 Kali
Update Terakhir :
13-06-2019 12:05

Detail Produk

 

Spesifikasi Automatic Aniline Point Apparatus

Alat Laboratorium Umum

K10290 Automatic aniline point aparatus 220-240V 50/60HZ

K10200 Automatic aniline point aparatus 115V 60HZ

Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.

  • Conforms to ASTM D611 and related specifications
  • For samples ranging from clear to very dark
  • Temperature range 0°C to 150°C (32°F to 302°F)
  • Digital temperature displayPerforms aniline point and mixed aniline point determinations automatically by means of a modified thin film technique (ASTM D611 Method E). The sample-aniline mixture is directly heated by a platinum immersion heater and the aniline point is detected photoelectrically. Temperature is displayed on a large LED indicator. Built-in pressure regulator and solenoid valve permit the use of cooling air for quicker cooling cycles or to determine subambient aniline point temperatures. Aniline points as low as 0°C (32°F) can be determined with the use of refrigerated cooling air. Equipped with variable controls for heater, light source and stirrer speed. Cabinet exterior surfaces have a chemical resistant polyurethane enamel finish.
  • Standard Borosilicate Glass Test Cell with drain

    Conforms to the specifications of: ASTM D611; IP 2; ISO 2977; DIN 51775; FTM 791-3601; NF M 07-021

    Testing Range: 0 to 150°C (32 to 302°F)

    Temperature Display: 0-999.9°C115V 60Hz, Single Phase, 0.4A
    220-240V 50/60Hz, Single Phase, 0.2A

    Ixwxh,in.(cm): 14 1⁄2x8 1⁄2x20 3⁄4 (37x22x53)

    Net Weight: 31lbs (14.1kg)

    Shipping Weight: 46 lbs (20.9 kg)

    Dimensions: 28x24x20 in. (71.2x61.0x50.8 cm)

    Shipping Weight: 46 lbs (20.9 kg)

    Dimensions: 28x24x20 in. (71.2x61.0x50.8 cm)

  • 250-000-33F ASTM 33F Thermometer - Range: –36.5 to +107.5°F 1
  • 250-000-33C ASTM 33C Thermometer - Range: –38 to +42°C
  • 250-000-34F ASTM 34F Thermometer - Range: 77 to 221°F 1
  • 250-000-34C ASTM 34C Thermometer - Range: 25 to 105°C
  • 250-000-35F ASTM 35F Thermometer - Range: 194 to 338°F 1
  • 250-000-35C ASTM 35C Thermometer - Range: 90 to 170°C
  • K10210 Borosilicate Glass Test Cell with drain
  • K10220 Heating-Cooling Tube with platinum element

Harga Automatic Aniline Point Apparatus

 : CALL

Permintaan Penawaran