Automatic Pensky Martens Closed Cup Flash Point Tester

Harga :
Rp. 1 / unit
Merk :
KOEHLER
Pembelian Minimal :
1 unit
Pengiriman :
3 hari sejak pembayaran
Lokasi :
DKI Jakarta - Jakarta Pusat
Dilihat :
2 Kali
Update Terakhir :
13-06-2019 11:36

Detail Produk

 

Spesifikasi Automatic Pensky Martens Closed Cup Flash Point Tester

Alat Laboratorium Umum

K7100 Automatic pensky martens closed cup flash point analizer 110-240 50/60 hz

For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing.

  • Conforms to ASTM D93 and related specifications
  • Flash Point Detection by Thermocouple and Ionization Ring
  • Electric or Gas ignition: Software selectable, User Friendly Manual Switching
  • Flash Point operation range between Ambient and 405°C
  • Integrated Dual Fan System directly cools test cup and surrounding
  • environment
  • 8.4” LCD Touch Screen Interface makes for easy viewing and navigation
  • Automatic Barometric Pressure Correction
  • Fire Suppression System floods instrument with inert gas in the event of a fireThe Automated Pensky-Martens Flash Point Analyzer represents a perfect union of next-generation technology with traditional robust quality. The system software runs on an integrated processor PC running the latest Windows operating system. The 8.4” touch screen interface fully displays all operator parameters and results on a single screen. A three (3) position mechanical lift system for the cover and motor assembly is fully automated and software selectable: Open – Clean – Test for one touch positioning of the test cup. Comes standard with two flash detector systems including a thermocouple and ionization ring detection. Over 65,000 results of data can be stored on the local hard drive. Integrated Dual Fan System directly cools the test cup and the environment around test cup. Unlimited number of user programs including a quick test that safely tests from ambient, puts the flash point result into the EFP of the official run, and prompts user to refresh the sample, virtually assuring no fires ever occur. In addition, the instrument comes standard with an inert gas fire suppression system

    Conforms to the specifications of: 

    ASTM D93 Procedure A, B and C; IP 34; ISO 2719; DIN EN 22719; JIS K2265; NF M 07-019

    Detection System: Thermocouple and Ionization Ring

    Temperature Range: Ambient - 405°C

    Heating Rate: In accordance to ASTM D93 procedure A, B and C

    Stirring Rate: 0 to 300 ± 5 RPM

    Cycle Time: 5 minutes as per rapid fan cooling system Ignition Test Frequency: User selectable on per method basis

    Cooling:

    Integrated Dual Fan System: First (1) directly to cup, Second(2) to cool environment around test cup

    Barometric Pressure: Automatic Barometric Pressure Correction

    Methods & Data Storage: Limited only by PC hard disk drive space

    Temperature Calibration: Three Types come standard:
     2 Point Sample Temperature
     Multipoint (>2) Temperature Calibration
    CRM Calibration – Built-In Software function to automatically correct as per CRM tested

     

    Communication: LIMS Connectivity via Ethernet and RS 232 ports. Two (2) USB ports (1 – Frontm 2 – Back)

    Security: Three (3) level password protection

    Safety: Fire prevention, detection, and suppression systems standard110-240V 50/60Hz

    wxdxh,in.(cm): 10 7/8 x 17.5 x 26 (27.63x44.45x66.04)

    Net Weight: 60 lbs (27.22kg)

    Shipping Weight:74 lbs (33.6 kg)

    Dimensions: 25x19x29 in. (63.5x48.3x73.7 cm)