Spesifikasi LPG Copper Strip Corrosion Test Apparatus
Alat Laboratorium Umum
K39900 LPG corrosion test water bath 115v 60 hz
K39990 LPG corrosion test water bath 220-240v 50/60 hz
K39901 Digital LPG corrosion test water bath 115v 60 hz
K39991 Digital LPG corrosion test water bath 220-240v 50/60 hz
Tests the corrosiveness of LPG to copper by immersion of a polished test strip in the sample inside a test cylinder at elevated temperature. After one hour the test strip is removed and compared against the ASTM Copper Strip Corrosion Standards
- Conforms to ASTM D1838 and related specifications
- Four-sample testing capabilityConsists of LPG Corrosion Test Cylinders, Water Bath, Copper Strips, Polishing Materials and the ASTM Copper Strip Corrosion Test Standards. LPG Corrosion Test Cylinders–Stainless steel cylinder with 1⁄4" needle valves for purging and admitting LPG samples. Dip tube with hook suspends copper strip in sample. Knurled, threaded cap with O-ring gasket hand tightens to a positive seal. Withstands hydrostatic test pressure of 1000 psig (6895kPa). LPG Corrosion Test Water Bath–Thermostatically controlled water bath submerges four LPG Corrosion Test Cylinders in an upright position. Controls temperature at 100 ±1°F (37.8 ±0.5°C) per ASTM specifications. Soxhlet reflux condenser and constant water level device maintain proper working depth. Polished stainless steel inner wall and powder coated steel outer wall construction. Fully insulated.
Conforms to the specifications of:
ASTM D1838; GPA 2140; ISO 6251 Water Bath Specifications:
Capacity: four (4) LPG Corrosion Test Cylinders
Maximum Temperature: 21°F (105°C)
Temperature Control Stability: ±1°F (±0.5°C)
Heater Range: 0-750W
Bath Medium: 3.8 gal (14.4L) Water
Conforms to the specifications of:
ASTM D1838; GPA 2140; ISO 6251 Water Bath Specifications:
Capacity: four (4) LPG Corrosion Test Cylinders
Maximum Temperature: 21°F (105°C)
Temperature Control Stability: ±1°F (±0.5°C)
Heater Range: 0-750W
Bath Medium: 3.8 gal (14.4L) Water115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 3.4Alxwxh,in.(cm): 12x10x24 (30x25x61)
Net Weight: 25 lbs (11.3 kg)Shipping Weight: 31 lbs (14.1 kg)
Dimensions: 24x20x18 in. (61.0x50.8x45.7 cm)
- K40000 LPG Corrosion Test Cylinder
- K40200 Copper Strip for LPG
- 12.5x1.5-3.0x75mm with
- 3.2mm hole per ASTM specifications
- K40100 Connecting Tubing
- Sulfur-free plastic-lined tubing for connection of test
- cylinder valve to sample source. With 1⁄4 " stainless
- steel and aluminum connectors. 24" long
- K25100 ASTM Copper Strip Corrosion Test Standards
- Colored reproductions of tarnished strips
- encased in a plastic plaque.
- 380-240-001 Silicone Carbide Paper, 240-grit
- For polishing copper strips prior to testing.
- Pack of 50 sheets
- 380-150-000 Silicone Carbide Grain, 150-grit
- For final polishing of copper strips prior to testing.
- 1 lb package
- 380-150-001 Silicone Carbide Paper, 150-grit
- For polishing copper strips prior to testing.
- Pack of 50 sheets
- K25000 Polishing Vise
- Holds copper strip firmly in place without marring the edges. Stainless steel, mounted on a composition base
- K25090 Multi-Strip Polishing Vise
- Similar to K25000 but capable of holding four
- strips at a time
- 250-000-12F ASTM 12F Thermometer. Range: –5 to +215°F
- 250-000-12C ASTM 12C Thermometer. Range: –20 to +102°C