DKI Jakarta - Jakarta Pusat

Fluke 17Plus

Harga :
Rp. 1 / unit
Merk :
FLUKE
Pembelian Minimal :
1 unit
Pengiriman :
3 hari sejak pembayaran
Lokasi :
DKI Jakarta - Jakarta Pusat
Dilihat :
5 Kali
Update Terakhir :
29-05-2019 12:53

Detail Produk

 

Spesifikasi Fluke 17Plus

Alat Ukur Kuat Arus

Description

Fluke 17B+ Digital Multimeter adalah alat yang digunakan untuk pengukuran umum dasar listrik ditambah suhu, frekuensi dan siklus. Fluke 17B+ mudah digunakan dengan satu tangan, bahkan jika Anda menggunakan sarung tangan. Akurasi Fluke 17B+ ditentukan selama 1 tahun setelah kalibrasi, pada suhu operasi 18°C hingga 28°C, dan kelembaban relatif pada 0% sampai 75%.

Features:

• 600 V Cat III safety rating
• 50% bigger display with bright white backlight
• Over-voltage indicator
• Frequency and temperature measurement
• Voltage, resistance, continuity, capacitance
• Input terminal for ac and dc current measurements to 10 A current
• Diode test, data hold

Spesifikasi – Fluke 17B+ Digital Multimeter

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3
AC millivolts 400.0 mV 0.1 mV 3.0 % + 3
DC millivolts 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1
Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty Cycle1 1 % to 99 % 0.1 % 1 % typical 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
Temperature 50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
0.1C 2 % ± 1 °C
± 2 °C
9 % ± 2 °C
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.

 

Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max

 

General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (HxWxL) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be

Harga Fluke 17Plus

 : CALL
 

Dapatkan penawaran terbaik untuk
Fluke 17Plus !

Nama
Quantity
Unit
MINTA PENAWARAN

Produk Lainnya

Alat Ukur Kuat Arus Xray Dosimetry System - Fluke RaySafe X2
Alat Ukur Kuat Arus

Harga : IDR Call

Jakarta
Alat Ukur Kuat Arus Xray Dosimetry System - Fluke RaySafe X2
Alat Ukur Kuat Arus

Harga : Call

Jakarta
Fluke 1750
Alat Ukur Kuat Arus

Harga : IDR Call

Jakarta
Fluke 830
Alat Ukur Kuat Arus

Harga : IDR Call

Jakarta
Fluke 561 HVAC
Alat Ukur Kuat Arus

Harga : IDR Call

Jakarta

PERUSAHAAN TERKAIT

Putra Andalas Prima

Verified IconVerified
Indotrading gold member
1 Tahun
Response Rate 62%
Turboterm
Turboterm
Turboterm

Hamoda Tools

Verified IconVerified
Indotrading gold member
2 Tahun
Response Rate 43%
Turboterm
Turboterm
Turboterm

Berkat Teknik Sentosa

Verified IconVerified
Indotrading gold member
1 Tahun
Response Rate 90%
Turboterm
Turboterm
Turboterm
Perusahaan
ANDALAN BANGUN SEJAHTERA

 
3 Tahun
Response Rate :
reply_all40%
 
Jl. Sumur Batu no. 1 Kemayoran Jakarta Pusat Jakarta Pusat, DKI Jakarta - Indonesia
 

Permintaan Penawaran